Laminar Flow Üniteleri (LAF)

The MEGE Laminar Flow Unit is a high-efficiency air distribution plenum designed to deliver unidirectional, laminar airflow with uniform velocity across the protected area. It effectively reduces particulate and microbial contamination by maintaining controlled airflow patterns and creating a continuous sweeping effect that minimizes turbulence and prevents re-entrainment of airborne particles.

Açıklama

Technical Specifications

MEGE Laminar Flow Unit is constructed from stainless steel, offering high resistance to the abrasive and chemical effects of disinfectants commonly used in controlled and sterile environments.

At the center of the MEGE Laminar Flow Unit, a large mounting opening is provided to accommodate and conceal the operating theatre lamp mounting flange along with associated electrical components, ensuring a flush and unobstructed installation.

The MEGE Laminar Flow Unit is equipped with an integrated test channel designed to verify the airtightness between the filter housing and the filter sealing interface, ensuring reliable leak-free performance.

During manufacturing, leak tightness testing is performed in accordance with DIN 25414 standard. A test aerosol sampling probe is utilized to measure the aerosol concentration at the filter inlet, enabling precise verification of the filter sealing integrity.

MEGE Laminar Flow Units are selected based on the dimensions of the protected area and the specific requirements of the operating room to ensure optimal airflow performance and contamination control.

The size of the protected area varies depending on the type and duration of the operation. The airflow rate is designed to provide a minimum of 25 air changes per hour (ACH), with a minimum airflow capacity of 2400 m³/h to ensure effective contamination control.

The size of the protected area varies depending on the type and duration of the operation. The airflow rate is designed to provide a minimum of 25 air changes per hour (ACH), with a minimum airflow capacity of 2400 m³/h to ensure effective contamination control.

Product Code

Air Winding Surface

Dimensions
(WxHxD)

Flow Rate

Initial Pressure Drop

Number of Entries

Entry Dimension

Filter Dimension

mm

mm

mm

mm

m³/h

Pa

qty

mm

mm

MGLF-S-4-14-34S-EC

1200×2400

1269

2469

445

2500 – 2800

180

2

285 x 585

305 x 610 x 292

MGLF-S-4-14-34S-EC

1400×2400

1469

2469

445

2900 – 3350

100

4

285 x 585

305 x 610 x 292

MGLF-S-4-14-34S-EC

1600×2400

1669

2469

445

3300 – 3850

120

4

285 x 585

305 x 610 x 292

MGLF-S-4-14-34S-EC

1800×2400

1869

2469

445

3750 – 4200

140

4

285 x 585

305 x 610 x 292

MGLF-S-4-14-34S-EC

2000×2400

2069

2469

445

4150 – 4650

155

4

285 x 585

305 x 610 x 292

MGLF-S-4-14-34S-EC

2200×2400

2269

2469

445

4600 – 5100

165

4

285 x 585

305 x 610 x 292

MGLF-S-4-14-34S-EC

2400×2400

2469

2469

445

5000 – 5600

180 – 125

4-6

285 x 585

305 x 610 x 292

MGLF-S-4-14-34S-EC

3200×2400

3269

2469

445

6700 – 7500

150

6

285 x 585

305 x 610 x 292

MGLF-S-4-14-34S-EC

2600×2600

2590

2590

445

5400 – 6100

60

4

200 x 600

305 x 610 x 292

MGLF-S-4-14-34S-EC

2800×2800

2800

2800

445

6300 – 7100

60

4

200 x 1000

305 x 610 x 292

MGLF-S-4-14-34S-EC

3200×3200

3200

3200

445

8300 – 9350

60

4

200 x 1000

305 x 610 x 292